E5053A microwave downconverter E5052B microwave downconverter for SSA
Category:
Signal source analyzer
Product Attachment:
- Product Description
- Selection
-
- Brand: 是德科技
- Commodity name: E5053A microwave downconverter E5052B microwave downconverter for SSA
- Brand: Keysight Technologies
Keysight E5053A Microwave Downconverter: A Core Expansion Module for High-Frequency Signal Analysis
I. Product Positioning and Core Functions
- Frequency Extension Capability Supports direct downconversion from 3 GHz to 26.5 GHz, and can be extended to 110 GHz with the 11970 series harmonic mixer, covering 5G millimeter wave (28 GHz/39 GHz), automotive radar (77 GHz/79 GHz), and terahertz bands (above 100 GHz).
- Phase Noise Enhancement Using cross-correlation technology, it can reduce background noise by 10-20 dB, improving the phase noise measurement sensitivity of high-frequency signals (e.g., a typical phase noise value of -178 dBc/Hz at 26.5 GHz).
- Seamless Integration It is deeply compatible with the E5052B/E5055A signal source analyzers. Direct control via the SSA interface is possible without additional configuration, supporting real-time spectrum monitoring and transient analysis functions.
II. Technical Parameters and Performance Advantages
- Cross-Correlation Technology Through dual-channel independent downconversion, it eliminates random noise interference, improving phase noise sensitivity by more than 10 dB at 26.5 GHz compared to traditional methods.
- Real-time Spectrum Monitoring Captures signal spectrum in real-time within a 15 MHz sweep range, supporting burst interference detection (such as nonlinear distortion of radar chirp signals).
- Transient Analysis Simultaneously monitors changes in frequency, phase, and power over time. Combined with video triggering, it can capture microsecond-level frequency jumps (such as transient fluctuations in satellite communication signals).
III. Typical Application Scenarios
- Millimeter-wave PA Testing In conjunction with the E5052B, it measures the ACPR (adjacent channel power ratio) and EVM (error vector magnitude) of 28 GHz 5G NR signals, verifying the linearity of base station power amplifiers.
- 6G Terahertz R&D Extended to 110 GHz via the 11970 mixer, it analyzes the phase noise and modulation accuracy of terahertz band signals, supporting preliminary research on 6G ultra-high-speed communication systems.
- 77 GHz FMCW Signal Analysis Measures the linearity and phase noise of automotive radar, ensuring the target recognition accuracy of ADAS systems.
- Terahertz Non-destructive Testing In conjunction with a terahertz mixer, it analyzes defects in the hot-melt joints of polyethylene pipes, improving industrial inspection efficiency.
- Ka-band Signal Verification Tests the phase noise and frequency stability of satellite communication equipment, ensuring the reliability of satellite-ground links.
- Radar Anti-jamming Optimization Real-time monitoring of the spectral purity of radar signals, suppressing the impact of stray signals on navigation systems.
IV. Comparison with Similar Products
- Cost-effectiveness Used market prices are only 20%-50% of similar new products, and it supports seamless integration with E5052B/E5055A, reducing system setup costs.
- Technological Leadership Correlation technology and low-noise design make it superior to competitors in high-frequency phase noise measurement, especially suitable for scientific research and high-end R&D scenarios.
-
I. Core Hardware Options
1. Frequency Extension and Interface Adaptability
2. Mechanical Installation and Expansion
3. Calibration and Maintenance
II. Supporting Software and Functions
1. Host Compatibility Requirements
2. Special Application Support
III. Key Considerations
- The E5053A only supports E5052B/E5055A Signal Source Analyzers It cannot operate independently.
- Millimeter-wave measurement requires 11970 Series Mixers (e.g., 11970B: 26.5 GHz~40 GHz; 11970D: 50 GHz~75 GHz).
- It is recommended to calibrate through a Keysight Technologies certified laboratory every 12 months to ensure down-conversion accuracy (typical value ±0.5 dB).
- Calibration kit (such as E5053A-1A7) needs to be used with E5052B host calibration procedure Usage.
- The E5053A has been discontinued, the replacement model is E5053B ,which supports a wider frequency range (10 MHz~7 GHz) and better phase noise performance (-134 dBc@1 GHz/20 kHz).
- Inventory still exists in the secondary market, but compatibility with the host and warranty status need to be confirmed.
Product Consultation
Please fill out the form below, leave your contact information and needs, and we will be happy to serve you!


