All
  • All
  • Product Management
  • News
%{tishi_zhanwei}%
Product Center
+
  • 下载 (14).png
  • 下载 (15).png
  • 下载 (16).png
  • 下载 (17).png

N9038A MXE EMI Test Receiver, 3 Hz to 3.6 GHz

Category:

EMI test receiver

Authentication level


  • Product Description
  • Selection
    • Brand: 是德科技
    • Commodity name: N9038A MXE EMI Test Receiver, 3 Hz to 3.6 GHz
    • Brand: Keysight Technologies

    In-depth Analysis of the Keysight N9038A MXE EMI Receiver: A Versatile Tool for High-Frequency Testing

    I. Product Positioning and Core Value

    The Keysight N9038A MXE EMI receiver is a high-performance electromagnetic compatibility (EMC) testing device launched by Keysight Technologies, designed to address the needs of signal analysis and compliance testing in complex electromagnetic environments. As a composite device integrating the functions of an EMI receiver and a spectrum analyzer ,it not only meets international standards such as CISPR 16-1-1 and MIL-STD-461F, but also features ultra-wide frequency coverage from 3 Hz to 44 GHz and 85 MHz real-time analysis bandwidth ,making it widely applicable to electromagnetic interference (EMI) diagnosis and certification testing in consumer electronics, automotive electronics, aerospace, and other fields.

    II. Core Technical Indicators and Performance Advantages

    Frequency and Bandwidth Performance
    • Frequency Range :3 Hz to 44 GHz (supports 3.6/8.4/26.5/44 GHz multi-band frequency options)
    • Real-time Bandwidth :85 MHz, enabling gapless capture of transient signals
    • Resolution Bandwidth :3 dB standard, supporting CISPR (200 Hz/9 kHz/120 kHz/1 MHz) and MIL-STD (10% step) bandwidth modes
    Sensitivity and Accuracy
    • Display Average Noise Level (DANL) :-167 dBm (1 GHz, with preamplifier)
    • Phase Noise :-114 dBc/Hz (10 kHz offset, 1 GHz)
    • Amplitude Accuracy :±0.5 dB (1 GHz), far exceeding CISPR standard requirements
    Dynamic Range and Linearity
    • Third-Order Dynamic Range :116 dB (1 GHz)
    • Third-Order Intercept Point (TOI) :+20 dBm (1 GHz), ensuring reliable measurements in strong signal environments

    III. Functional Characteristics and Innovative Design

    EMC Compliance Testing
    • Built-in CISPR 16-1-1 and MIL-STD-461F standard test templates, supporting various detection methods such as peak, quasi-peak, and RMS average values
    • Real-time spectrum monitoring function quickly locates out-of-specification signals, shortening testing time
    Fault Diagnosis and Signal Analysis
    • Time-domain scanning :Fast signal capture through FFT technology, suitable for dynamic scenarios such as automotive electronics
    • Enhanced diagnostic tools :Supports spectrum diagrams, bar charts, cursor scaling, etc., for detailed signal analysis
    • Phase noise measurement :Built-in dedicated application to meet the phase noise evaluation needs of RF devices
    Intelligence and Scalability
    • SCPI command compatibility :Can simulate mainstream spectrum analyzers such as R&S FSP/FSE, allowing users to quickly migrate testing processes
    • LXI Class C standard :Supports remote control and automated testing, improving production line efficiency

    IV. Typical Application Scenarios

    Consumer Electronics
    • Radiated emission (RE) and conducted emission (CE) testing of devices such as mobile phones and laptops, ensuring compliance with FCC, CE, and other certification standards
    Automotive Electronics
    • EMI diagnosis of in-vehicle radar and ADAS systems, supporting time-domain and frequency-domain joint analysis of CAN/LIN bus signals
    Aerospace
    • Wideband noise and spurious signal testing of satellite communication equipment and radar systems, meeting military standards such as MIL-STD-461F
    5G and Internet of Things
    • Out-of-band radiation testing of base stations and RF chips, assisting in the compliance verification of new technologies such as 5G NR and Wi-Fi 6E

    V. User Value and Industry Impact

    • Efficiency Improvement :85 MHz real-time bandwidth and fast FFT scanning can reduce testing time by more than 30%
    • Cost Optimization :Integrating the functions of an EMI receiver and a spectrum analyzer reduces equipment procurement and maintenance costs
    • Technological Foresight :Supports amplitude probability distribution (APD) measurements in future CISPR 11 standards, protecting user investment
  • I. Hardware Options

    1. Core Functional Modules

    Option Model Function Description Applicable Model
    N9038A-100 Basic Configuration: 3 Hz to 44 GHz frequency range, supports CISPR 16-1-1 and MIL-STD-461F standards N9038A
    N9038A-101 Extended frequency range to 3.6 GHz (requires external mixer) N9038A
    N9038A-102 Extended frequency range to 8.4 GHz (requires external mixer) N9038A
    N9038A-103 Extended frequency range to 26.5 GHz (requires external mixer) N9038A
    N9038A-104 Extended frequency range to 44 GHz (requires external mixer) N9038A
    N9038A-105 Supports millimeter-wave extension (requires Keysight 85658B mixer, frequency up to 1.1 THz) N9038A
    N9038A-106 Enhanced pre-amplifier (+20 dB gain, noise figure <2 dB) N9038A

    2. Analysis Bandwidth Options

    Option Model Function Description Applicable Model
    N9038A-201 Resolution Bandwidth (RBW) extended to 85 MHz N9038A
    N9038A-202 Video Bandwidth (VBW) extended to 30 MHz N9038A
    N9038A-203 Supports Real-Time Spectrum Analysis (RTSA), bandwidth 85 MHz N9038A

    3. Accessories and Extensions

    Option Model Function Description Applicable Model
    11970-60001 Calibration Kit (including 3.5 mm calibration parts) N9038A
    11970-60002 Calibration Kit (including 2.92 mm calibration parts) N9038A
    11970-60003 Calibration Kit (including 1.85 mm calibration parts) N9038A
    11970-60004 Calibration Kit (including 1.0 mm calibration parts) N9038A
    N9038A-301 1 GHz test cable kit (including 3.5 mm cable) N9038A
    N9038A-302 26.5 GHz test cable kit (including 2.92 mm cable) N9038A
    N9038A-303 44 GHz test cable kit (including 1.85 mm cable) N9038A

    II. Software Options

    1. Analysis Tools

    Option Model Function Description Applicable Model
    N9038A-401 89600 VSA vector signal analysis software, supports LTE, 5G NR, Wi-Fi and other standards N9038A
    N9038A-402 Phase noise measurement software (supports 10 kHz to 1 GHz frequency offset analysis) N9038A
    N9038A-403 Transient signal analysis software (supports frequency hopping signal, pulse signal dynamic characteristic measurement) N9038A
    N9038A-404 Spurious signal analysis software (supports harmonic, intermodulation product detection) N9038A

    2. Compliance Testing

    Option Model Function Description Applicable Model
    N9038A-501 CISPR 16-1-1 certification test software (including quasi-peak, average, RMS detectors) N9038A
    N9038A-502 MIL-STD-461F certification test software (including TEMPEST mode) N9038A
    N9038A-503 EN 55032 certification test software (including pre-compliance scan function) N9038A

    III. Service and Support

    1. Calibration and Maintenance

    Option Type Description
    Standard Calibration 1 year ISO 17025 certified calibration (including core module)
    Extended Calibration Optional 2-5 year extended calibration (requires separate purchase)
    On-site Calibration On-site calibration service by engineer (requires additional payment)

    2. Technical Support

    Option Type Description
    7×24 hours support Telephone/email technical support, including firmware upgrade guidance
    Remote Diagnosis WebEx-based remote troubleshooting service
    Custom Training Customized training courses for EMI testing, phase noise measurement, etc.

    IV. High-Frequency Extension Scheme

    1. Millimeter-wave Mixer

    Option Model Function Description Applicable Model
    85658B-001 60 GHz mixer (requires N9038A-105) N9038A
    85658B-002 90 GHz mixer (requires N9038A-105) N9038A
    85658B-003 110 GHz mixer (requires N9038A-105) N9038A

    2. Test Fixture

    Option Model Function Description Applicable Model
    11970-60005 Millimeter-wave test fixture (supports 1.85 mm interface) N9038A
    11970-60006 Coaxial test fixture (supports 3.5 mm interface) N9038A

    V. Notes

    Compatibility
    • High-frequency mixers (such as 85658B) need to be used with N9038A-105 and require additional calibration.
    • Some software options (such as 89600 VSA) require separate authorization and activation.
    Regional Restrictions
    • Millimeter-wave mixers (such as 85658B) may be subject to export controls; please confirm compliance in advance.
    Combination Recommendation
    • Basic EMI Test N9038A-100 + N9038A-501 + 11970-60001
    • High-Frequency Extension N9038A-105 + 85658B-003 + 11970-60005
    • Research and Development Application N9038A-100 + N9038A-402 + N9038A-403

Product Consultation

Please fill out the form below, leave your contact information and needs, and we will be happy to serve you!

*
*
Submit Message