E5062A ENA-L RF Network Analyzer, 300 kHz to 3 GHz

Category:

Desktop network analyzer

Network analyzer


  • Product Description
  • Selection
    • Brand: 是德科技
    • Commodity name: E5062A ENA-L RF Network Analyzer, 300 kHz to 3 GHz
    • Brand: Keysight Technologies

    I. Basic Performance and Parameters

    Frequency Range
    Coverage 300kHz to 3GHz Suitable for basic testing of low-frequency RF components and circuits, such as CATV (cable television) components and low-frequency filters.
    Dynamic Range and Accuracy
    • Dynamic Range : 120dB (with 10Hz IF bandwidth), effectively distinguishing strong signals from weak signals, showing stable performance when measuring low-loss cables or high-gain amplifiers.
    • Trace Noise : 0.005dB rms (with 3kHz IFBW), ensuring the repeatability and reliability of measurement results.
    • Temperature Stability : 0.01dB/°C (typical value), maintaining data consistency during long-term testing.
    Measurement Speed
    • Fast Scan : Scanning 201 points takes only 25ms (with 30kHz intermediate frequency bandwidth), suitable for mass production testing or R&D scenarios requiring quick verification.
    • Flexible Configuration : Supports linear, logarithmic, and segmented scan modes, optimizing testing efficiency according to the characteristics of the device under test.

    II. Functional Features and Options

    Core Measurement Functions
    • T/R or S-parameter Measurement : Supports transmission/reflection (T/R) testing instruments or full two-port S-parameter testing instruments to meet different accuracy requirements.
    • Port Impedance Selection : Provides 50Ω and 75Ω system impedances, adapting to special applications such as CATV components.
    • Extended Power Range : Option 1E1 can extend the output power to -45 to 10dBm, suitable for testing devices requiring a wide power range.
    Advanced Functions and Options
    • Fault Location and SRL Analysis : Option 100 supports time-domain analysis, which can locate fault points in cables or transmission lines and perform return loss (SRL) analysis.
    • Built-in VBA Programming : Supports automated testing through Visual Basic for Applications, simplifying complex measurement processes.
    • Color Touch Screen : Option 016 is equipped with a color touch screen, improving ease of operation.
    Calibration and Accessories
    • Electronic Calibration (ECal) : Optional electronic calibration components, completing two-port calibration through a single connection, reducing errors caused by manual operation.
    • Abundant Test Accessories : Supports various connectors such as 50Ω and 75Ω N-type and F-type, adapting to different devices under test.

    III. Application Fields

    Communication and Consumer Electronics
    • Testing antennas, filters, amplifiers, and other wireless communication devices, as well as CATV splitters, distribution amplifiers, and other cable television components.
    • Evaluating the transmission characteristics of PCB board-level circuits, such as differential signal integrity analysis.
    Automotive Electronics
    • Measuring the S-parameters of in-vehicle radars and RF modules to ensure their stable performance in complex electromagnetic environments.
    Education and Research
    • Used as a teaching tool to help students understand the basic principles of RF network analysis; used in research for material dielectric property testing or new device development.
    Industry and Production
    • Performing fast consistency testing of passive devices such as RF cables and connectors on production lines to improve quality inspection efficiency.

    IV. Replacement Models and Upgrade Paths

    The E5062A has been discontinued, and its replacement model is E5061B (belonging to the ENA series), which has improvements in frequency range (5Hz to 3GHz), functional integration (such as built-in DC bias source), etc. If higher frequency bands or more complex functions are needed, consider E5080B (covering up to 53GHz) or PNA series network analyzers.
  • I. Hardware Options

    1. Test Fixture and Port Configuration

    T/R Test Option
    • 150 : 50Ω system impedance, supports transmission/reflection (T/R) testing, suitable for low-cost scenarios.
    • 175 : 75Ω system impedance, suitable for cable television (CATV) component measurement, such as splitters and distribution amplifiers.
    S-parameter Test Option
    • 250 : 50Ω system impedance, extended power range (-45 to +10 dBm), supports full two-port calibration, improves measurement accuracy.
    • 275 : 75Ω system impedance, also has an extended power range, suitable for 75Ω impedance CATV device testing.

    2. Functional Expansion

    • 100 : Fault Location Analysis, supports Structural Return Loss (SRL) testing, can quickly locate impedance discontinuities in cables or PCBs.
    • 016 : Color touchscreen LCD, enhances intuitive operation, simplifies parameter setting and result viewing.
    • 1E1 : Extended power range (-45 to +10 dBm), covers the testing needs of low-power to medium-power devices.

    3. Calibration and Accessories

    • 85032F : N-type mechanical calibration kit, covering 30 kHz to 9 GHz, includes open, short, and load standards to ensure measurement accuracy. 1
    • 85092C : Electronic Calibration (ECal) module, supports fast two-port calibration, reduces human operation errors.
    • N-type test cable : Such as 8120-6469 (50Ω) and 8120-6468 (75Ω), adapt to different impedance testing needs.

    II. Software Functions

    • Built-in VBA Programming : Supports automated test script development, allows customization of measurement processes through Visual Basic for Applications, improves batch testing efficiency.
    • Time Domain Analysis : Achieves TDR (Time Domain Reflectometer) measurement through option 100 or built-in function, locates transmission line faults or impedance anomalies.
    • Multiple Scan Modes : Supports linear, logarithmic, and power scans, adapting to the testing needs of different devices such as filters, cables, and amplifiers.

    III. Key Parameters and Comparison

    Parameter E5062AE5071C56E5080B516
    Frequency Range 300 kHz to 3 GHz 9 kHz to 20 GHz 9 kHz to 53 GHz
    Dynamic Range 120 dB (10 Hz IFBW) 140 dB (10 Hz IFBW) 140 dB (10 Hz IFBW)
    Port Impedance 50/75 Ω 50 Ω 50 Ω
    Typical Applications Basic RF testing, CATV components RF component development, 5G intermediate frequency testing Millimeter-wave devices, high-speed interconnect analysis

    IV. Application Scenarios

    Wireless Communication
    • Test antennas, filters, and amplifiers' S-parameters, support basic performance evaluation of 50Ω impedance devices.
    • Combine with option 100 for cable fault location, optimize signal transmission quality.
    Cable Television (CATV)
    • 75Ω impedance support, suitable for insertion loss and return loss testing of splitters and distribution amplifiers.
    • Extend the power range through option 275 to verify the stability of high-power devices.
    Automotive Electronics
    • Evaluate the RF performance of in-vehicle radar and communication modules to ensure reliability in complex electromagnetic environments.
    Education and Research
    • Built-in VBA and multiple scan modes, suitable for teaching demonstrations and basic RF experiments, reducing learning costs.

    V. Discontinued and Replacement Suggestions

    E5062A has been discontinued, the replacement model is E5071C (9 kHz to 20 GHz) or E5080B (9 kHz to 53 GHz) 1 . For higher frequency or dynamic range, consider upgrading to E5080B; if the budget is limited and the frequency requirement does not exceed 20 GHz, E5071C is a more economical choice.

Product Consultation

Please fill out the form below, leave your contact information and needs, and we will be happy to serve you!

*
*
Submit Message